TRIMM, INC.
High Current Power Distribution Unit
This family of power distribution panels go up to 600A per side and use either fuses or breakers. You can also use the optional Smart Meter Module to monitor the voltage and amperage being used on each bus. The Smart Meter Module can use remote temperature sensors to monitor the temperature in two different locations. All of this information is displayed locally and can be monitored remotely.

< Download the HCPDU Fuse Panel Datasheets.
Click on the part number below for a marketing drawing.
TPS, TLS, TPC, TPW Fuse Panel/Circuit Breaker Panel
Bookmark and Share
BREAKER/FUSE POSITIONS INPUT TYPE OUTPUT TYPE PART NUMBER RACK MTG SMM
Smart Meter Module
RFQ
10A/10B Comp. Lug Comp. Lug 7671100001 23" 2U N GET A QUOTE
8A/8B Comp. Lug Comp. Lug 7678800003 19" 2U N GET A QUOTE
8+5A/8+5B (8 HC, 5 GMT) Comp. Lug Comp. Lug/Barrier Strip 7678800111 23" 2U N GET A QUOTE
6+5A/6+5B (6 HC, 5 GMT) Comp. Lug Comp. Lug/Barrier Strip 7676600113 19" 2U N GET A QUOTE
10A/10B Comp. Lug Comp. Lug 7671101001 23" 4U N GET A QUOTE
6+5A/6+5B (6 HC, 5 GMT) Comp. Lug Comp. Lug/Barrier Strip 7676610111 23" 2U Y GET A QUOTE
6+5A/6+5B (6 HC, 5 GMT) Comp. Lug Comp. Lug/Barrier Strip 7676611111 23" 4U Y GET A QUOTE
8+5A/8+5B (8 HC, 5 GMT) Comp. Lug Comp. Lug/Barrier Strip 7678801111 23" 4U N GET A QUOTE
8A/8B Comp. Lug Comp. Lug 7678810001 23" 2U Y GET A QUOTE
8A/8B Comp. Lug Comp. Lug 7678811001 23" 4U Y GET A QUOTE
4A/4B Comp. Lug Comp. Lug 7674410003 19" 2U Y GET A QUOTE
4A/4B Comp. Lug Comp. Lug 7674411003 19" 4U Y GET A QUOTE
6+5A/6+5B (6 HC, 5 GMT) Comp. Lug Comp. Lug/Barrier Strip 7676601113 19" 4U N GET A QUOTE

Marketing drawings and installation instructions are in Adobe® Acrobat® pdf file format



-ACCESSORIES-
GMT Fuses
PART NUMBER AMPERAGE RFQ
0300097000 18/100 GET A QUOTE
0300097001 1/4 GET A QUOTE
0300097002 1/2 GET A QUOTE
0300097003 3/4 GET A QUOTE
0300097004 1 GET A QUOTE
0300097005 1-1/3 GET A QUOTE
0300097006 1-1/2 GET A QUOTE
0300097007 2 GET A QUOTE
0300097008 3 GET A QUOTE
0300097013 3-1/2 GET A QUOTE
0300097012 4 GET A QUOTE
0300097009 5 GET A QUOTE
0300097011 7-1/2 GET A QUOTE
0300097010 10 GET A QUOTE
0300097014 12 GET A QUOTE
0300097015 15 GET A QUOTE
0300097100 Dummy GET A QUOTE
Click here for the GMT Fuse Specification Sheet


767 Family Fuse Panel Accepted Fuse and Circuit Breaker Types
Fuses require holders listed at start of each column (order separately)
TPC FUSES
Uses TPCDS fuse holder part number 0300108180
PART NUMBER AMPERAGE RFQ
0300360003 3 AMP GET A QUOTE
0300360004 4 AMP GET A QUOTE
0300360005 5 AMP GET A QUOTE
0300360006 6 AMP GET A QUOTE
0300360007 7 AMP GET A QUOTE
0300360008 8 AMP GET A QUOTE
0300360010 10 AMP GET A QUOTE
0300360012 12 AMP GET A QUOTE
0300360015 15 AMP GET A QUOTE
0300360020 20 AMP GET A QUOTE
0300360025 25 AMP GET A QUOTE
0300360030 30 AMP GET A QUOTE
0300360040 40 AMP GET A QUOTE
0300360050 50 AMP GET A QUOTE
0300360060 60 AMP GET A QUOTE
0300360075 75 AMP GET A QUOTE
0300360090 90 AMP GET A QUOTE
0300360100 100 AMP GET A QUOTE
0300360125 125 AMP GET A QUOTE
TPS FUSES
Uses TFD fuse holder part number 0300108380
PART NUMBER AMPERAGE RFQ
0300350001 1 AMP GET A QUOTE
0300350002 2 AMP GET A QUOTE
0300350003 3 AMP GET A QUOTE
0300350005 5 AMP GET A QUOTE
0300350006 6 AMP GET A QUOTE
0300350010 10 AMP GET A QUOTE
0300350015 15 AMP GET A QUOTE
0300350020 20 AMP GET A QUOTE
0300350025 25 AMP GET A QUOTE
0300350030 30 AMP GET A QUOTE
0300350035 35 AMP GET A QUOTE
0300350040 40 AMP GET A QUOTE
0300350050 50 AMP GET A QUOTE
0300350060 60 AMP GET A QUOTE
0300350070 70 AMP GET A QUOTE
TLS Fuses
Uses TFD fuse holder part number 0300108380
PART NUMBER AMPERAGE RFQ
0300390001 1 AMP GET A QUOTE
0300390003 3 AMP GET A QUOTE
0300390005 5 AMP GET A QUOTE
0300390006 6 AMP GET A QUOTE
0300390010 10 AMP GET A QUOTE
0300390015 15 AMP GET A QUOTE
0300390020 20 AMP GET A QUOTE
0300390025 25 AMP GET A QUOTE
0300390030 30 AMP GET A QUOTE
0300390035 35 AMP GET A QUOTE
0300390040 40 AMP GET A QUOTE
0300390050 50 AMP GET A QUOTE
0300390060 60 AMP GET A QUOTE
0300390070 70 AMP GET A QUOTE
0300390080 80 AMP GET A QUOTE
0300390090 90 AMP GET A QUOTE
0300390100 100 AMP GET A QUOTE
0300390125 125 AMP GET A QUOTE
TPW Fuses (2 Pole)
Uses TPWDS fuse holder part number 7600108280*
PART NUMBER AMPERAGE RFQ
0300380150 150 AMP GET A QUOTE
0300380175 175 AMP GET A QUOTE
0300380200 200 AMP GET A QUOTE
0300380225 225 AMP GET A QUOTE
0300380250 250 AMP GET A QUOTE
*Holder includes 2 pole adapter kit and 2 pole output cover
Circuit Breakers
PART NUMBER AMPERAGE RFQ
030017760A 5 AMP GET A QUOTE
030017760B 7.5 AMP GET A QUOTE
030017760C 10 AMP GET A QUOTE
030017760D 15 AMP GET A QUOTE
030017760E 20 AMP GET A QUOTE
030017760F 25 AMP GET A QUOTE
030017760G 30 AMP GET A QUOTE
030017760H 40 AMP GET A QUOTE
030017760I 50 AMP GET A QUOTE
030017760J 60 AMP GET A QUOTE
030017760K 70 AMP GET A QUOTE
030017760L 80 AMP GET A QUOTE
030017760M 90 AMP GET A QUOTE
030017760N 100 AMP GET A QUOTE
2 Pole Circuit Breakers*
PART NUMBER AMPERAGE RFQ
039017771A 110 AMP GET A QUOTE
039017771B 120 AMP GET A QUOTE
039017771C 130 AMP GET A QUOTE
039017771D 140 AMP GET A QUOTE
039017771E 150 AMP GET A QUOTE
*Includes 2 pole adapter kit and 2 pole output cover

Blank Plug*
PART NUMBER RFQ
7600161501 GET A QUOTE
*Blank Plugs Protect Unfilled Positions
Product Links
GMT Fuse Panels (OV) ; GMT Fuse Panels (8") ; KLM Fuse Panels ; GMT/KLM Fuse Panels ; TPA Fuse Panels
GMT/TPA Fuse Panels ; TPS Fuse Panels ; TPM Fuse Panels ; GMT/TPM Fuse Panels ; "OV" Series Circuit Breaker Panels
Total Front Access GMT Fuse Panels ; High Current Power Distribution Unit

Trimm, Inc. 407 Railroad St. Butner, North Carolina 27509
Phone:  (800) 298-7466 Fax:  (919) 575-6200

© 2000-2010 Trimm Inc. All rights reserved.